Downdraft
Technologies Preventative Maintenance Services
- Replace
all replaceable filters - intake/burner, ceiling, exhaust (all filters
are included in price) *
- Pressure
Wash Booth Interior, Doors and Frontal
- Pressure
Wash Grates and Pans
- Clean liquid
mask and paint overspray from walls, doors, and glass
- Clean all
glass in doors and light panels
- Check panels
for leaks, seal as needed
- Check and
Adjust blower belts and pulleys for proper tension, alignment and wear
- Grease motors,
blowers, linkage and dampers
- Check for
loose and missing bolts
- Adjust linkage
as needed
- Check and
adjust doors and latches
- Clean Door
Gaskets and replace gaskets if needed
- Check electrical
system & panel for proper operation
- Replace
bulbs/ballasts as needed*
- Check for
proper pneumatic operation and check oilers and oil trap for water /
air separator as applicable
- Check Intake
and Exhaust air ducts for obstructions and proper fan operation*
- Clean, Scrape
& vacuum exhaust dampers & chamber - Adjust as needed
Direct
Fired Gas (or Propane) Burner Service (included with Annual Booth Service)
- Tune-up
direct fired gas fired burner assembly - adjust for maximum efficiency
- Clean sight
glass & gas orifices
- Remove and
clean burner pilot assembly
- Clean burner
ports and profile
- Check Hi-Lo
burner operation as applicable
- Clean or
replace burner filters as applicable
- Perform
recommended factory updates to burner and controls
Total for Annual Preventative Maintenance Service $ 1,995*